Ion Chromatography MCI GEL™ HPLC Columns

The MCI GEL™ ion chromatography columns are based on surface functionalized cation and anion exchange resins designed for non-suppressed ion chromatography applications. The non-suppressed ion chromatography is an analysis technique of cations and anions with combination of a packed column of low capacity ion exchange resin and low concentration of electrolyte solution as an eluent. The advantage of the ion chromatography is that several ions can be analyzed by only one injection with free of complicated sample pre-treatment.

MCI GEL™ SCK01
Packing material of MCI GEL™ SCKO1 is crosslinked polystyrene functionalized with sulfonic acid. This column is characterized by excellent resolution and rapid analysis for monovalent and divalent cations. Standard monovalent cations like Li+, Na+, NH4+, K+, Rb+, Cs+ and simple amines such as mono-, di- and trimethylamine can be resolved using a nitric acid solution as eluent. Divalent cations, such as alkaline earth metals and transition metal elements, can be efficiently resolved using tartaric acid and complexing reagent such as ethylene diamine to selectively elute the metals from the column.

Note: When using the MCI GEL™ SCKO1 column for monovalent cations, it is recommended that a pre-column, MCI GEL™ SCK-PC, be used to trap heavy metals which might otherwise poison the SCK01 column resulting in a rapid loss of capacity and chromatographic performance.

MCI GEL™ CHK45/C05
Packing material of MCI GEL™ CHK45/C05 is made of crosslinked polymethacylate functionalized with carboxylic acid. By use of simple eluent system, MCI GEL™ CHK45/C05 can separate both monovalent and divalent cations in tap water, river water and other environmental water samples.

MCI GEL™ SCA04
Packing material of MCI GEL™ SCA04 is based on a hydrophilic viniyl polymer matrix functionalized with quaternary ammonium group and particle size of 5 μm. A solution of potassium hydrogen phthalate and a vanilic acid (VA)/N-methyldiethanolamine (MDEA) solution both can be used as a mobile phase. The unique VA/MDEA eluent, is developed for the SCA04 column, which allows users to determine 7 standard anions in 14 minutes without system peak.